How Can a Cable Fail a Certification Test Yet Still Pass Data?

29/11/2017

How Can a Cable Fail a Certification Test Yet Still Pass Data?

A common question that comes up with certification is “how can a cable fail a certification test yet still pass data”? To answer this question, it is necessary to understand the differences between the performance requirements for various data speeds and cabling performance categories. The best place to start is the frequency requirements of each and the difference between frequency and data rate.

Data Rate

Data rate is the amount of data passed through the cable or network measured in megabits per second (Mb/s). Data rate is key metric in defining Ethernet speeds and is a function of the signalling frequency and the type of encoding used to create data bits. Common data rates available on twisted pair cabling are 10, 100, 1000 (1G) and 10G. 40G has just become available and 25G will be available shortly, though the distance is limited to 30 meters vs 100 meters with the other data rates.

Cable Frequency

Cable frequency is the frequency at which the cable is tested for certification. The difference between the cable frequency and data rate is due to the encoding used to create the data bits and the number of pairs used to transmit data.

Notice the discrepancies between the cable frequency and the data rate between the various types of Ethernet. 1000Base-T or 1G Ethernet is the most common application in use today and while it requires only Class D cabling to operate most people are installing class E or EA cabling which are certified to 250 and 500 MHz respectively. Therefore, the cabling is being tested at up to 5x the speed that is required for the network to operate properly. In this scenario, a cable can fail a certification test for Class E/EA and still work perfectly fine on a 1000Base-T network because of the significant difference in what is tested vs the minimum operating requirements. In short, many assume Class E/Cat 6 cable is required to support 1G data when in fact Class D/Cat 5e is all that Is required.

In Conclusion

The most common reason for the difference in the class of installed cabling and the data rate of the network equipment being used is to prepare for future applications. Today, the cost of 10G switches still hover around $300 per port while 1G switches cost $5-10 per port. 10G is still too costly for use at every work station and is limited mostly to data centres, but the cost difference between Class E and EA cabling is small enough that many organisations will pay for the better cabling to ensure they can migrate to 10G networks when the costs come down in the future. So even though a 1G network will run fine on poor quality Class EA cabling today, the infrastructure must be designed and tested to support future applications when organisations are ready to deploy them.

Recent articles

  • New Quick Setup Cable Certifier from IDEAL Networks 23/10/2018

    Designed to support busy cable installers, the new Quick Setup mode on the latest version of the IDEAL Networks LanTEK III enables almost all configuration and testing to be performed on just one straightforward screen.

    Read more
  • New touchscreen testers save time network testing and troubleshooting 03/10/2018

    IDEAL Networks has added touchscreens to several of its network and data cable testers to make troubleshooting and transmission testing quicker and easier than ever before. 

    Read more
  • 4 IDEAL Networks Touchscreen Testers to Save You Time 01/10/2018

    We know that time is crucial for technicians testing and troubleshooting cable and network installations, so for faster and easier network troubleshooting, cable installation and transmission testing, we have introduced touchscreens to some of our popular IDEAL Networks testers.

    Read more
  • IDEAL Networks to showcase latest tester developments at GITEX 2018 25/09/2018

    IDEAL Networks will exhibit at GITEX from 14th – 18th October 2018 in Dubai to present recent enhancements to its wide range of network, data cable and IP CCTV testers.

    Read more
  • Need Help Testing Modular Plug Terminated Links? 18/09/2018

    IDEAL Networks explains answers common questions about the challenges of the testing and certification of Modular Plug Terminated Links.

    Read more